BSKRV - SURFACE MOUNT SOLDER CAPLETTES, 6-SN63
- MSDS: BSKRV
- Manufacturer: ESP SOLDER PLUS
- Product Name: SURFACE MOUNT SOLDER CAPLETTES, 6-SN63
- National Stock Number: 3439-00N047615
Product Identification
Product ID:SURFACE MOUNT SOLDER CAPLETTES, 6-SN63
MSDS Date:01/07/1991
FSC:3439
NIIN:00N047615
MSDS Number: BSKRV
Responsible Party
LINCOLN, RI 02865
US
Emergency Phone: 401-333-3800
Info Phone: 401-333-3800
Cage: ESPS0
Contractor
Telephone: 401-333-3800
Cage: ESPS0
Ingredients
TIN
CAS: 7440-31-5
RTECS: XP7320000
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
OSHA PEL 0.05 MG/M3
ACGIH TLV: 0.15 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
BISMUTH
CAS: 7440-69-9
RTECS: EB2600000
OSHA PEL N/K
ACGIH TLV: N/K
ROSIN ACID; (ROSIN)
CAS: 8050-09-7
OSHA PEL N/K
ACGIH TLV: N/K
ALPHA-TERPINEOL; (TERPENE)
CAS: 98-55-5
RTECS: WZ6700000
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGESTION OF LEAD ALLOYS IS
TOXIC & WILL PRODUCE POISONING. BREATHING OF VAPORS MAY PRODUCE
RESP IRRIT. INHALATION OR INGESTION MAY PRODUCE NAUS, VOMIT, HDCH,
JOINT & MUSCLE PAIN. MAY CAUSE DERM AT. MAY IRRITATE EYES. LEAD
APPEARS ON THE NAVY LISTING OF OCCUP CHEM REPRODUCTIVE HAZARDS .
SEEK (EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CONSULTATION FROM APPROPRIATE HEALTH
PROFESSIONALS CONCERNING LATEST HAZARD LIST INFORMATION AND SAFE
HANDLING AND EXPOSURE INFORMATION .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:REMOVE CONTACT LENSES, IMMED FLUSH W/PLENTY OF WATER FOR
AT LEAST 15 MINUTES AND GET MED ATTN. SKIN:WASH THOROUGHLY WITH
SOAP AND WARM WATER. INHAL:REMOVE TO FRESH AIR. INGEST:IF
OVER-EXPOSURE IS SUSPECTED , OBTAIN A MEDICAL EVALUATION OF BLOOD
LEAD LEVEL. SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:COC
Flash Point:210F,99C
Extinguishing Media:DRY CHEMICAL, FOAM, CO*2.
Fire Fighting Procedures:IF LG QUANTITIES OF SOLDER ARE ON FIRE,
NIOSH/MSHA APPROVED SCBA SHOULD BE USED, AS TOXIC FUMES MAY BE
EMITTED.
Unusual Fire/Explosion Hazard:FLUX IN SOLDER MAY BURN IF SOLDERING IS
DONE WITH A FLAME.
Accidental Release
Spill Release Procedures:PUT INTO PROPERLY LABELED WASTE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID STORAGE NEAR HEAT OR OPEN
FLAMES.
Other Precautions:OPERATOR SHOULD BE PROTECTED FROM SOLDERING FUMES.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MAINTAIN ADEQUATE EXHAUST. LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS RUBBER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NOT REQUIRED.
Work Hygienic Practices:WASH HANDS THOROUGHLY PRIOR TO EATING, DRINKING
OR SMOKING. DO NOT SMOKE WHILE SOLDERING.
Supplemental Safety and Health
BP:FLUX-306F,202C; ALLOY->1112F>600C. SPEC GRAV:FLUX-<1; SOLDER->4.
Chemical Properties
Boiling Pt:B.P. Text:SUPDAT
Melt/Freeze Pt:M.P/F.P Text:>280F,>138C
Spec Gravity:SUPDAT
Solubility in Water:0
Appearance and Odor:FLUX-AMBER GEL, MILD ODOR; SOLDER-GREY CREAM, MILD
ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:MOISTURE.
Hazardous Decomposition Products:NONE KNOWN.
Disposal
Waste Disposal Methods:DISPOSE OF ACCORDING TO FEDERAL, STATE AND LOCAL
REGULATIONS. SOLDER MAY BE SENT TO A METALS RECLAIMER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.